1.1.3 Format A Inputs
Three connectors can be used by third-party inputs: the common DB-50 connectors, the
MADI A Inputs, and the DB-25 AES connectors. The appropriate signal is chosen
according to the following rules:
If the MADI switch is ON, the MADI input is used for all 56 channels.
If the MADI switch is OFF, either the common DB-50 or AES signals are used in
eight-channel banks.
If only one connector is in use, that format is selected.
If both are connected, the common DB-50 signal takes precedence.
Format A Adapters
To create a compact 2U device with maximum flexibility, the FC727/726 uses a com-
mon DB-50 connector for all third-party formats. An adapter is required to convert from
the DB-50 connector to the company’s own connector. The adapter is not intended to
be the connecting cable; it simply adapts the common DB-50 connector so it behaves
like the rear panel of the third-party device. These adapters are available separately
from Euphonix. In most cases, another cable is required to connect the adapter to the
third-party device. For example, a cable is required to connect the FC727 to a Pro Tools
computer just as it would be to connect to an 888-24 I/O unit. See Appendix A: Pinout
and Cable Specifications for detailed information.
1.1.4 Sample Rate Conversion
Digital audio devices have previously been required to use the same sample rate to op-
erate correctly together. The FC727/726 removes this limitation by allowing many
sample rates simultaneously. For example, by using the common DB-50 connectors,
each eight-channel bank can operate at its own sample rate. Furthermore, the FC727/
726 detects different sample rates and automatically activates SRC.
Although the FC727/726’s SRC is the highest quality available, some users may
still require an unaltered, bit-for-bit copy of the data. In this case, connected devic-
es can be slaved to the same sample clock, which disables SRC automatically (you
can also disable SRC manually).